Complementary |
Assembly style |
For customer assembly |
Net weight |
0.015 kg |
Contact operation |
Slow-break |
Positive opening |
Without |
Operating travel |
2.6 mm (NO changing electrical state)
4.3 mm (total travel) |
Operating force |
2.3 N NO changing electrical state |
Operating torque |
0.05 N.m NO changing electrical state |
Mechanical durability |
10000000 cycles |
Connections - terminals |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1 |
Tightening torque |
0.8…1.2 N.m conforming to IEC 60947-1 |
Shape of screw head |
Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver |
Contacts material |
Silver alloy (Ag/Ni) |
Maximum resistance across terminals |
25 MOhm |
Short-circuit protection |
10 A cartridge fuse type gG conforming to IEC 60947-5-1 |
[Ith] conventional free air thermal current |
10 A conforming to IEC 60947-5-1 |
[Ui] rated insulation voltage |
600 V (pollution degree 3) conforming to IEC 60947-1 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-1 |
[Ie] rated operational current |
3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1 |
Electrical durability |
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Electrical reliability |
Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA conforming to IEC 60947-5-4 |
Additional information |
Mounting on integrated plate in the box |
Electrical composition code |
SR1 (quantity <= 3)
SR2 (quantity <= 2)
MR1 (quantity <= 2) |