top of page
Thermal overload relay LR9G 115A push-in front

Thermal overload relay LR9G 115A push-in

TeSys LR9G 115A thermal overload relay is compatible with TeSys Giga high power contactor, push-in control connection. It provides phase imbalance, phase failure, in-built ground-fault and single-phase loads protections. It is available for manual and auto reset options and LED indicator for Motor ON and pre-trip alarm. Tripping classes is selectable from class 5E to class 30E to suit different application needs from fast tripping, general purpose and high inertia loads. It is suitable for independent mounting or direct mounting with LC1G contactors. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature without derating up to 3000m altitude. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.

SKU: LR9G115
  • Product Info

    Range TeSys
    Product name TeSys LRG
    Product or component type Electronic thermal overload relay
    Device short name LR9G
    relay application Motor protection
    Network type AC
    Thermal overload class Class 5E...30E conforming to IEC 60947-4-1
    Thermal protection adjustment range 28…115 A
    Complementary
    Network frequency 30...60 Hz
    100 Hz
    Overvoltage category III
    Tripping threshold 1.125 +/- 0.07 In conforming to IEC 60947-4-1
    Protection type Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to IEC 60947-4-1
    Ground fault protection - tripping time adjustment: 0…1 s - for alarm circuit conforming to UL 60947-4-1
    Phase loss - tripping time adjustment: 0…4 s - for alarm circuit
    Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to IEC 60947-4-1
    Phase imbalance - tripping time adjustment: 0…5 s - for alarm circuit conforming to UL 60947-4-1
    local signalling LED
    Trip indicator
    Contacts type and composition 1 NO + 1 NC
    [Ith] conventional free air thermal current 5 A
    [Uc] control circuit voltage 24...500 V AC 50/60 Hz
    24...250 V DC
    [Ue] rated operational voltage 1000 V AC 50/60 Hz
    [Uimp] rated impulse withstand voltage 8 kV
    Reset Automatic reset
    Manual
    Mechanical durability 7000 cycles
    Surge withstand 4 kV
    Electromagnetic compatibility EMC immunity conforming to IEC 60947-4-1
    Emission tests criteria A conforming to IEC 60947-4-1
    Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3
    Voltage dips and interruptions immunity test conforming to SEMI F47
    Connections - terminals Power circuit: bar - busbar cross section: 25 x 6 mm
    Power circuit: lugs-ring terminals 1 185 mm²
    Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end
    Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end
    Control circuit: push-in 2 0.5…1.0 mm² with cable end
    Tightening torque 18 N.m
    Mounting support Direct on contactor
    Plate
    Standards EN/IEC 60947-4-1
    EN/IEC 60947-5-1
    UL 60947-4-1
    CSA C22.2 No 60947-4-1
    JIS C8201-4-1
    JIS C8201-5-1
    product certifications CB Scheme
    CCC
    cULus
    UKCA
    ATEX
    EU-RO-MR by DNV-GL
    EAC
    Environment
    IP degree of protection IP2X front face with shrouds conforming to IEC 60529
    IP2X front face with shrouds conforming to VDE 0106
    Protective treatment TH
    Ambient air temperature for operation -25…60 °C
    Ambient air temperature for storage -60…80 °C
    Permissible ambient air temperature around the device -40…60 °C at Uc
    Adjustment of dial setting -25…60 °C
    Mechanical robustness Vibrations 5…300 Hz 6 gn contactor open
    Shocks 15 gn 11 ms contactor closed
    height 107 mm
    Width 105 mm
    Depth 126 mm
    Net weight 0.9 kg
    Colour Dark grey
    Packing Units
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Height 17.0 cm
    Package 1 Width 20.0 cm
    Package 1 Length 21.0 cm
    Package 1 Weight 1.416 kg
    Unit Type of Package 2 S03
    Number of Units in Package 2 2
    Package 2 Height 30.0 cm
    Package 2 Width 30.0 cm
    Package 2 Length 40.0 cm
    Package 2 Weight 3.4 kg
  • Return & Refund Policy

  • Shipping Info

No Reviews YetShare your thoughts. Be the first to leave a review.