top of page
TRIP UNIT MICROLOGIC 6.0 P front

TRIP UNIT MICROLOGIC 6.0 P

Range : Masterpact 
-  range of product : Masterpact NTMasterpact NW 
-  product or component type : Control unit 
-  trip unit name : Micrologic 6.0 P 
-  trip unit technology : Electronic 
-  range compatibility : Masterpact NT06...16Masterpact NW08...40Masterpact NW40b...63 
-  device application : Distribution 
-  Number of poles : 3P4P 
-  protected poles description : 4t3t3t + N/2 
-  trip unit protection functions : Selective + earth
- fault protection 
-  protection type : for overload protection (long time) for short time short-circuit protection for instantaneous short-circuit protection for earth fault 
-  Trip unit rating : 630 A at 50 °C800 A at 50 °C1000 A at 50 °C1250 A at 50 °C1600 A at 50 °C2000 A at 50 °C2500 A at 50 °C3200 A at 50 °C4000 A at 50 °C5000 A at 50 °C6300 A at 50 °C 
-  network type : AC 
-  network frequency : 50/60 Hz 
-  Circuit breaker mounting mode : FixedDrawout

SKU: 47059
  • Product Info

    Control Type 3P
    4P
    Display Type digital display
    Product Or Component Type control unit
    Trip Unit Name Micrologic 6.0 P
    Network Type AC
    Protected Poles Description 3t
    3t + N/2
    4t
    Range Compatibility ComPact NS
    Masterpact MT
    Masterpact NT
    Masterpact NW
    PowerPact P-Frame
    PowerPact R-Frame
    Range Name MicroLogic
    Trip Unit Protection Functions selective + earth-fault protection
    Trip Unit Technology electronic
    Type Of Measurement power meter
    COMPLEMENTARY
    Analogue Output Number digital display
    Product Name Micrologic
    Communication Of Data maintenance indicators
    measurement readout
    protection and alarm settings
    Device Application distribution
    Earth-leakage Protection without
    Ground-fault Pick-up Adjustment Type adjustable 9 settings
    Ground-fault Time Delay Adjustment Type -tg adjustable
    Instantaneous Pick-up Adjustment Type Ii adjustable 9 settings
    Long Time Delay Adjustment Type adjustable 9 settings
    Long Time Pick-up Adjustment Range 0.4...1 x In
    Long Time Pick-up Adjustment Type Ir adjustable 9 settings
    Mounting Mode drawout
    fixed
    Network Frequency 50/60 Hz
    Short-time Delay Adjustment Type adjustable
    Short-time Pick-up Adjustment Type Isd adjustable 9 settings
    Thermal Memory 20 mn
    Zone Selective Interlocking ZSI with
    [Ig] Ground-fault Pick-up Adjustment Range 0.2...1 x In for 400 A < In < 1250 A
    0.3...1 x In for In <= 400 A
    500...1200 A for In >= 1250 A
    [Isd] Short-time Pick-up Adjustment Range 1.5...10 x Ir
    [tg] Ground-fault Time Delay Adjustment Range 0.1-0.4 s I²t=on
    0-0.4 s I²t=off
    [tr] Long-time Delay Adjustment Range 0.7-16.6 s at 7.2 x Ir
    0.7-24 s at 6 x Ir
    12.5-600 s at 1.5 x Ir
    [tsd] Short-time Delay Adjustment Range 0.1-0.4 s I²t=on
    0-0.4 s I²t=off
    ENVIRONMENT
    Ambient Air Temperature For Operation -25-70 °C
    Ambient Air Temperature For Storage -40-85 °C
    OTHER
    Earth Leakage Current Micrologic 6.0 P
    Poles Description 3P
    4P
  • Return & Refund Policy

  • Shipping Info

No Reviews YetShare your thoughts. Be the first to leave a review.
bottom of page